Water level sensor in steam generator tank faulty
Quick Answer
Error code F144 on your AEG Ovens means: Water level sensor in steam generator tank faulty. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Sensor failure
  2. Limescale blocking sensor
  3. Wiring issue
  4. Tank position incorrect
How to Fix It
1
Check the water tank is properly seated
2
Clean the water level sensor
3
Descale the steam system
4
Replace the water level sensor