Pressure Switch Stuck Closed
Quick Answer
Error code 31 on your Carrier Central Air Conditioners & Furnaces means: Pressure Switch Stuck Closed. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Pressure switch contacts welded or stuck in closed position
  2. Incorrect pressure switch installed with wrong pressure rating
  3. Pressure switch hose connected to wrong port
  4. Water trapped in pressure switch hose holding switch closed
How to Fix It
1
Disconnect the pressure switch hose and verify the switch opens (use a multimeter for continuity)
2
Inspect the hose for trapped water or condensation and drain if needed
3
Verify the correct pressure switch is installed by comparing part numbers to the wiring diagram
4
Replace the pressure switch if contacts are welded closed
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Pressure switch
Pressure switch tubing
Hose clamps