C
e2
Moderate
Carrier · Central Air Conditioners & Furnaces
Indoor Coil Freeze Protection
Quick Answer
Error code E2 on your Carrier Central Air Conditioners & Furnaces means: Indoor Coil Freeze Protection. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Low refrigerant charge causing evaporator temperature to drop below freezing
  2. Dirty evaporator coil blocking airflow
  3. Blower motor failure reducing air across the coil
  4. Dirty air filter severely restricting return airflow
  5. Metering device stuck or restricted
How to Fix It
1
Turn system to fan-only mode to thaw the evaporator coil (may take 1-4 hours)
2
Check and replace the air filter
3
Inspect the evaporator coil for dirt buildup and clean if accessible
4
Once thawed, check refrigerant charge by measuring superheat and subcooling
5
Verify blower motor is operating at the correct speed for cooling mode
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Air filter
Evaporator coil cleaner
Refrigerant (if low charge is confirmed)
Related Error Codes
Video Guides
Loading video guides…
Search more on YouTube →