Condenser Temperature Sensor Fault
Quick Answer
Error code C5 on your Daikin Mini-Splits & Ductless Systems means: Condenser Temperature Sensor Fault. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Outdoor condenser thermistor failed or disconnected
  2. Sensor wire damaged during installation or by weather
  3. Connector corrosion at the outdoor PCB
  4. Sensor displaced from its mounting position on the coil
How to Fix It
1
Locate the condenser thermistor on the outdoor unit coil
2
Measure thermistor resistance and compare to the Daikin temperature-resistance chart
3
Check the wiring from the sensor to the outdoor PCB for continuity
4
Reseat the connector and verify proper pin contact at the outdoor PCB
5
Replace if the resistance reading is significantly out of range
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Condenser thermistor
Sensor wire
Weather-resistant connectors