D
f3
Moderate
Daikin · Mini-Splits & Ductless Systems
Discharge Temperature Too High
Quick Answer
Error code F3 on your Daikin Mini-Splits & Ductless Systems means: Discharge Temperature Too High. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Low refrigerant charge causing compressor superheat
  2. Restricted expansion valve reducing refrigerant flow
  3. Compressor valve leakage causing recompression of hot gas
  4. System running in extreme high ambient conditions beyond rated range
How to Fix It
1
Check the discharge line temperature with a thermometer or thermocouple (should not exceed 225 degrees F)
2
Verify refrigerant charge by checking superheat and subcooling values
3
Inspect the expansion valve for proper operation
4
Check for restrictions in the liquid line or filter drier
5
A licensed HVAC technician should perform refrigerant system diagnostics and repairs
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Expansion valve
Filter drier
Refrigerant (R-410A or R-32)
Discharge thermistor