p1
Easy Fix
Mitsubishi Electric · Mini-Splits & Ductless Systems
Intake Air Temperature Sensor Fault
Quick Answer
Error code P1 on your Mitsubishi Electric Mini-Splits & Ductless Systems means: Intake Air Temperature Sensor Fault. This is usually fixable — see the step-by-step guide below.
Affected Models
Likely Causes
  1. Return air temperature thermistor disconnected or failed
  2. Thermistor wiring pinched or broken inside the indoor unit
  3. Connector corrosion at the indoor PCB
  4. Sensor reading outside the valid temperature range
How to Fix It
1
Locate the intake air thermistor near the return air grille of the indoor unit
2
Measure the thermistor resistance with a multimeter (approximately 10K ohms at 77 degrees F)
3
Check the connector at the indoor PCB for corrosion and reseat the connection
4
Inspect the sensor wire routing for pinching or damage
5
Replace the thermistor if resistance is out of the expected range
Pro Tip
This is a common issue that most users can resolve without specialized tools. Try the first step before moving on to more complex solutions.
Parts You May Need
Intake air thermistor
Wire connectors