12203
Moderate
Prusa · FDM 3D Printers
THERMAL_RUNAWAY Hotend - Temperature Deviated Beyond Safe Range
Quick Answer
Error code 12203 on your Prusa FDM 3D Printers means: THERMAL_RUNAWAY Hotend - Temperature Deviated Beyond Safe Range. This is usually fixable — see the step-by-step guide below.
Affected Models
Likely Causes
How to Fix It
1
Check that the silicone sock is properly fitted on the heat block
2
Verify the heater cartridge is firmly seated with the retention screw tightened
3
Run PID calibration from the printer menu: LCD > Settings > Temperature > PID Calibration
4
Ensure the print fan shroud is correctly installed and not directing air onto the heater block
5
If printing in a cold room, consider adding a draft shield or enclosure
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Silicone sock for E3D V6 or Nextruder (model dependent)
Heater cartridge (40W for MK3S+, 50W for MK4/MK4S)
Printer enclosure (Prusa original or third-party)