R
10 flashes
Moderate
Rheem · HVAC Systems & Water Heaters
12VDC Flame Sense Circuit Fault
Quick Answer
Error code 10 flashes on your Rheem HVAC Systems & Water Heaters means: 12VDC Flame Sense Circuit Fault. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Control board flame sensing circuit malfunction
  2. Flame sensor wiring shorted to the chassis ground
  3. Defective flame sensor with internal short
  4. Control board component failure in the 12VDC sensing circuit
How to Fix It
1
Disconnect the flame sensor wire and check the sensor resistance to ground (should be open/infinite)
2
Inspect the flame sensor wire insulation for damage that could cause grounding
3
Verify the flame sensor is not physically contacting the burner or chassis ground
4
If the sensor and wiring check out, the control board flame sensing circuit is likely failed
5
Control board replacement should be performed by a licensed HVAC technician
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Control board
Flame sensor
Sensor wire and connector
Related Error Codes
Video Guides
Loading video guides…
Search more on YouTube →