Y
1 blink
Moderate
York · HVAC Systems (AC, Furnaces, Heat Pumps & Thermostats)
System Lockout
Quick Answer
Error code 1 blink on your York HVAC Systems (AC, Furnaces, Heat Pumps & Thermostats) means: System Lockout. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. System has exceeded the maximum number of ignition retry attempts
  2. Repeated safety fault causing the control board to enter lockout mode
  3. Intermittent gas supply disruption during ignition cycles
  4. Multiple cascading faults triggering safety lockout
How to Fix It
1
Turn off furnace power for 60 seconds to reset the lockout condition
2
After reset, observe the LED for a different blink code that identifies the root cause
3
Check the ignition system including the igniter, flame sensor, and gas valve
4
Verify gas supply is on and pressure is adequate at the manifold
5
If lockout recurs after reset, a licensed HVAC technician should perform a full system diagnostic
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Hot surface igniter
Flame sensor
Control board
Related Error Codes
Video Guides
Loading video guides…
Search more on YouTube →