Temperature Reading Exceeds Maximum Safe Value
Quick Answer
Error code MAXTEMP on your Creality FDM 3D Printers means: Temperature Reading Exceeds Maximum Safe Value. This is usually fixable — see the step-by-step guide below.
Affected Models
Likely Causes
  1. Thermistor short circuit causing falsely low resistance reading
  2. Heater cartridge wires touching the thermistor wires causing electrical interference
  3. Damaged thermistor reporting incorrect values
  4. Incorrect thermistor type configured in Marlin firmware
How to Fix It
1
Immediately power off the printer to prevent genuine overheating
2
Inspect the hotend wiring for any crossed or touching wires between heater and thermistor
3
Measure thermistor resistance; if near 0 ohms at room temperature it is shorted
4
Verify the thermistor table in Marlin configuration matches the installed thermistor type (typically TEMP_SENSOR_0 = 1 for 100K NTC)