E
e11
Easy Fix
Electrolux · Dryers
Fill Valve Error
Quick Answer
Error code E11 on your Electrolux Dryers means: Fill Valve Error. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Steam dryer fill valve is not opening when steam cycle is selected
  2. Water supply to the steam dryer is turned off or disconnected
  3. Fill valve solenoid coil has failed electrically
  4. Water supply line to the dryer is kinked or frozen
How to Fix It
1
Verify the water supply faucet connected to the dryer steam feature is turned on
2
Inspect the water supply line for kinks, pinches, or ice blockages in cold environments
3
Disconnect the supply line and clean the inlet filter screen on the fill valve
4
Test the fill valve solenoid with a multimeter for continuity (expected 500-1500 ohms)
5
Replace the fill valve if the solenoid fails the continuity test
Pro Tip
This is a common issue that most users can resolve without specialized tools. Try the first step before moving on to more complex solutions.
Parts You May Need
Electrolux dryer fill valve (part #137353500)