eh0
Moderate
Electrolux · Dryers
Power Supply Voltage Error
Quick Answer
Error code EH0 on your Electrolux Dryers means: Power Supply Voltage Error. This is usually fixable — see the step-by-step guide below.
Affected Models
Applies to all models
Likely Causes
How to Fix It
1
Check the household circuit breaker panel for a tripped breaker on the dryer circuit; reset if needed
2
Use a multimeter to measure voltage at the dryer outlet (should read 240V for electric dryers, 120V for gas dryers)
3
Inspect the dryer power cord and plug for damaged prongs, loose terminal connections, or burned wire insulation
4
Check the outlet receptacle for loose wire connections or signs of arcing/burning
5
If voltage is correct at the outlet, the main control board power supply circuit may be faulty and should be replaced
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Dryer power cord (3-prong or 4-prong as required)
Wall outlet receptacle (if damaged)
Main control board (part #137070860, if power supply circuit is faulty)