Evaporator Fan Circuit Open - Fan Motor Circuit Failure
Quick Answer
Error code 5Y EF on your Frigidaire Refrigerators means: Evaporator Fan Circuit Open - Fan Motor Circuit Failure. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Evaporator fan motor winding has developed an open circuit
  2. Wiring to the fan motor has a complete break in the conductor
  3. Fan motor connector has pulled loose from vibration
  4. Control board fan driver MOSFET has failed
How to Fix It
1
Unplug the refrigerator and access the evaporator fan by removing the rear panel inside the freezer
2
Disconnect the fan motor wires and test for continuity across the motor leads (should show some resistance, not open)
3
If the motor reads open (infinite resistance), it has failed and must be replaced
4
Check the wiring from the motor connector back to the main board for any breaks
5
If the motor and wiring are good, the main control board fan output may be faulty
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Evaporator fan motor (model-specific)
Wire repair kit
Main control board (if fan driver is faulty)