Pressure Switch Stuck Closed
Quick Answer
Error code 2 flashes on your Goodman HVAC Systems (AC, Furnaces & Heat Pumps) means: Pressure Switch Stuck Closed. This is usually fixable — see the step-by-step guide below.
Likely Causes
How to Fix It
1
Disconnect the pressure switch hose and check if the switch opens using a multimeter for continuity
2
Inspect the hose for trapped water or condensation and drain if present
3
Verify the correct pressure switch part number is installed per the furnace data plate
4
Ensure the hose is connected to the correct port on the inducer housing
5
Replace the pressure switch if contacts remain closed without applied pressure
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Pressure switch
Pressure switch hose