Pressure Switch Stuck Closed
Quick Answer
Error code 2 flashes on your Goodman HVAC Systems (AC, Furnaces & Heat Pumps) means: Pressure Switch Stuck Closed. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Pressure switch contacts welded in the closed position
  2. Water trapped in the pressure switch hose holding switch closed
  3. Incorrect pressure switch installed with wrong pressure rating
  4. Pressure switch hose connected to incorrect tap on the inducer
How to Fix It
1
Disconnect the pressure switch hose and check if the switch opens using a multimeter for continuity
2
Inspect the hose for trapped water or condensation and drain if present
3
Verify the correct pressure switch part number is installed per the furnace data plate
4
Ensure the hose is connected to the correct port on the inducer housing
5
Replace the pressure switch if contacts remain closed without applied pressure