4 flashes
Easy Fix
Goodman · HVAC Systems (AC, Furnaces & Heat Pumps)
Open High Temperature Limit Switch
Quick Answer
Error code 4 flashes on your Goodman HVAC Systems (AC, Furnaces & Heat Pumps) means: Open High Temperature Limit Switch. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Dirty or clogged air filter restricting airflow
  2. Blower motor not operating or running at reduced speed
  3. Supply or return air registers closed or blocked
  4. Undersized ductwork causing excessive temperature rise
How to Fix It
1
Check and replace the air filter if dirty
2
Open all supply and return registers throughout the home
3
Verify the blower motor is running during the heating cycle
4
Measure temperature rise across the furnace (compare to nameplate range, typically 30-60 degrees F)
5
Check the blower motor capacitor and clean the blower wheel if dirty
Pro Tip
This is a common issue that most users can resolve without specialized tools. Try the first step before moving on to more complex solutions.
Parts You May Need
Air filter
High-limit switch
Blower motor capacitor