p6
Moderate
Mitsubishi Electric · Mini-Splits & Ductless Systems
Freeze / Overheat Protection
Quick Answer
Error code P6 on your Mitsubishi Electric Mini-Splits & Ductless Systems means: Freeze / Overheat Protection. This is usually fixable — see the step-by-step guide below.
Affected Models
Likely Causes
  1. Indoor coil freezing due to low airflow or low refrigerant
  2. Dirty filters causing insufficient air over the evaporator
  3. Indoor fan motor running at reduced speed
  4. Refrigerant undercharge from a system leak
How to Fix It
1
Clean or replace the indoor air filters immediately
2
Check the indoor coil for ice formation; if frozen, run in fan-only mode until thawed
3
Verify the indoor fan is running at the proper speed and the barrel is clean
4
Check for any obstructions blocking the indoor unit air intake or discharge
5
If the code persists after filter cleaning, a licensed HVAC technician should check the refrigerant charge
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Air filters
Indoor fan motor (if failing)
Refrigerant (R-410A)