p9
Moderate
Mitsubishi Electric · Mini-Splits & Ductless Systems
Pipe Temperature Sensor 2 Fault
Quick Answer
Error code P9 on your Mitsubishi Electric Mini-Splits & Ductless Systems means: Pipe Temperature Sensor 2 Fault. This is usually fixable — see the step-by-step guide below.
Affected Models
Likely Causes
  1. Secondary pipe thermistor disconnected from the refrigerant pipe
  2. Thermistor failed open or short circuit
  3. Connector damage at the indoor PCB for the secondary sensor
  4. Wiring fault along the sensor lead
How to Fix It
1
Locate the secondary pipe thermistor on the indoor unit piping
2
Measure thermistor resistance and compare to the manufacturer's chart
3
Verify the sensor is properly mounted to the pipe with good thermal contact
4
Check the connector at the PCB and inspect wiring for damage
5
Replace the sensor if out of specification
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Pipe thermistor (secondary)
Insulation tape
Sensor mounting clip