pa
Moderate
Mitsubishi Electric · Mini-Splits & Ductless Systems
Compressor Overcurrent (CT Error)
Quick Answer
Error code PA on your Mitsubishi Electric Mini-Splits & Ductless Systems means: Compressor Overcurrent (CT Error). This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Compressor drawing excessive current indicating mechanical failure
  2. Low voltage supply to the outdoor unit
  3. Compressor winding insulation breakdown
  4. Current transformer sensor on the outdoor board miscalibrated or failed
How to Fix It
1
Measure compressor running amperage with an external clamp meter and compare to nameplate RLA
2
Check voltage at the outdoor unit terminal block under load (must be within rated range)
3
Inspect the compressor winding resistance and insulation to ground with a megohmmeter
4
Check the outdoor PCB current sensor for proper operation
5
Compressor failure diagnosis and replacement must be performed by a licensed HVAC technician
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Compressor
Outdoor PCB
Compressor start components