u3
Moderate
Mitsubishi Electric · Mini-Splits & Ductless Systems
Open / Short Circuit Sensor Detection
Quick Answer
Error code U3 on your Mitsubishi Electric Mini-Splits & Ductless Systems means: Open / Short Circuit Sensor Detection. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. One or more outdoor unit sensors has an open or short circuit
  2. Sensor wire damaged by weather, animals, or UV exposure
  3. Connector corrosion on the outdoor PCB
  4. Multiple sensor failures from a power surge
How to Fix It
1
Identify which sensor is faulted by checking each outdoor sensor's resistance with a multimeter
2
Compare each reading to the Mitsubishi temperature-resistance chart for the current conditions
3
Inspect all outdoor sensor connectors at the PCB for corrosion and clean if needed
4
Check sensor wiring for physical damage along the routing path
5
Replace any sensor found to be open or shorted
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Outdoor temperature sensors (as identified)
Wire connectors
Sensor mounting hardware