Y
e4
Moderate
York · HVAC Systems (AC, Furnaces, Heat Pumps & Thermostats)
Discharge Temperature Sensor Fault
Quick Answer
Error code E4 on your York HVAC Systems (AC, Furnaces, Heat Pumps & Thermostats) means: Discharge Temperature Sensor Fault. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Discharge line thermistor disconnected or failed
  2. Sensor reading open or short circuit
  3. Damaged sensor wire at the outdoor unit
  4. Corroded connector at the outdoor control board
How to Fix It
1
Locate the discharge line thermistor on the compressor discharge pipe
2
Measure the thermistor resistance and compare to the manufacturer's temperature-resistance chart
3
Check the connector at the outdoor control board for corrosion or loose pins
4
Inspect the sensor wire for physical damage along its routing
5
Replace the thermistor if resistance is out of specification
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Discharge line thermistor
Insulation tape
Wire connectors