G
e3
Moderate
Goodman · HVAC Systems (AC, Furnaces & Heat Pumps)
High Pressure Switch Open
Quick Answer
Error code E3 on your Goodman HVAC Systems (AC, Furnaces & Heat Pumps) means: High Pressure Switch Open. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Dirty outdoor condenser coil blocking heat dissipation
  2. Condenser fan motor failure
  3. Refrigerant overcharge from improper service
  4. Restriction in the liquid line or filter drier
How to Fix It
1
Clean the outdoor condenser coil thoroughly with a garden hose and coil cleaner
2
Verify the condenser fan motor is running and check its amperage
3
Check for clearance around the outdoor unit (minimum 24 inches on all sides)
4
Inspect the liquid line for kinks or restrictions
5
A licensed HVAC technician should verify the refrigerant charge with gauges
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Condenser fan motor
High-pressure switch
Coil cleaner
Fan capacitor