24V Power Absent to Control Board
Quick Answer
Error code Steady OFF on your Goodman HVAC Systems (AC, Furnaces & Heat Pumps) means: 24V Power Absent to Control Board. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Blown fuse on the control board (3A or 5A)
  2. Failed 24V transformer
  3. Thermostat wiring short causing fuse to blow
  4. Main power supply disconnected or breaker tripped
How to Fix It
1
Verify the furnace circuit breaker is on and power switch is in the ON position
2
Check the 3A or 5A fuse on the furnace control board and replace if blown
3
Measure the 24V transformer output (should be 24-28VAC across the secondary)
4
If the fuse blows again immediately, disconnect thermostat wires to isolate a short
5
Reconnect wires one at a time to identify the shorted circuit
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
3A or 5A fuse
24V transformer
Thermostat wire