Lennox · HVAC Systems (AC, Furnaces & Heat Pumps)
Pressure Switch Stuck Open
Quick Answer
Error code 201 on your Lennox HVAC Systems (AC, Furnaces & Heat Pumps) means: Pressure Switch Stuck Open. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Blocked flue or combustion air intake pipe
  2. Failed or weak inducer motor not creating enough draft
  3. Cracked, kinked, or disconnected pressure switch hose
  4. Condensate drain blockage causing water backup into inducer
  5. Defective pressure switch diaphragm
How to Fix It
1
Inspect the flue pipe and combustion air intake for blockages such as ice, debris, or animal nests
2
Check pressure switch hose connections and inspect for cracks or water accumulation
3
Verify the inducer motor is running by listening for operation at the start of a heating cycle
4
Clear the condensate drain line using compressed air or a wet-dry vacuum
5
Measure draft pressure at the pressure switch port with a digital manometer and compare to the switch rating
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Pressure switch
Pressure switch tubing
Inducer motor assembly