Lennox · HVAC Systems (AC, Furnaces & Heat Pumps)
Gas Valve Relay Failure
Quick Answer
Error code 221 on your Lennox HVAC Systems (AC, Furnaces & Heat Pumps) means: Gas Valve Relay Failure. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Control board gas valve relay contacts burned or welded
  2. Internal relay coil failure on the control board
  3. Wiring short between gas valve and control board
  4. Power surge damage to the control board relay circuit
How to Fix It
1
Verify 24VAC is present at the gas valve leads during a call for heat
2
Check the gas valve coil resistance (typically 150-600 ohms)
3
Inspect wiring between the control board and gas valve for damage or loose connections
4
If the relay is clicking but no voltage reaches the gas valve, the control board needs replacement
5
Gas valve and control board replacement should be performed by a licensed HVAC technician
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Control board
Gas valve
Wiring harness