T
1 blink
Moderate
Trane · HVAC Systems (AC, Furnaces & Heat Pumps)
System Lockout - Retries Exceeded
Quick Answer
Error code 1 blink on your Trane HVAC Systems (AC, Furnaces & Heat Pumps) means: System Lockout - Retries Exceeded. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Repeated ignition failures causing safety lockout
  2. Persistent pressure switch or limit switch faults
  3. Control board shutting down after maximum retry attempts
  4. Intermittent gas supply interruption during ignition cycles
How to Fix It
1
Turn off power to the furnace for 60 seconds to reset the lockout
2
Check for other blink codes that may appear after reset to identify root cause
3
Inspect the ignition system including igniter, flame sensor, and gas valve
4
Verify gas supply pressure at the manifold (3.5 in WC for natural gas)
5
If lockout recurs after reset, a licensed HVAC technician should perform a full combustion analysis
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Hot surface igniter
Flame sensor
Control board