5 blinks
Moderate
Trane · HVAC Systems (AC, Furnaces & Heat Pumps)
Flame Sensed Without Gas Valve Call
Quick Answer
Error code 5 blinks on your Trane HVAC Systems (AC, Furnaces & Heat Pumps) means: Flame Sensed Without Gas Valve Call. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Leaking gas valve allowing fuel to pass when not energized
  2. Residual flame in the burner area from incomplete shutoff
  3. Short circuit in flame sensing circuit
  4. Faulty control board misreading flame sensor signal
How to Fix It
1
Immediately shut off gas supply to the furnace as this indicates a potential gas leak
2
Inspect the gas valve for signs of leaking using a combustible gas detector
3
Check flame sensor wiring for shorts or damage
4
Test the gas valve by disconnecting the leads and checking for gas flow (should be none)
5
This is a critical safety fault. A licensed HVAC technician must perform the diagnosis and repair
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Gas valve assembly
Flame sensor
Control board