6 blinks
Moderate
Trane · HVAC Systems (AC, Furnaces & Heat Pumps)
Ignition Failure / Lockout
Quick Answer
Error code 6 blinks on your Trane HVAC Systems (AC, Furnaces & Heat Pumps) means: Ignition Failure / Lockout. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Failed or cracked hot surface igniter
  2. Gas supply off or low gas pressure
  3. Dirty or misaligned burners
  4. Defective gas valve not opening
  5. Control board ignition timing fault
How to Fix It
1
Verify the gas supply is turned on and check other gas appliances for proper function
2
Remove and inspect the hot surface igniter for visible cracks or white discoloration
3
Measure igniter resistance (typically 40-200 ohms for silicon nitride igniters)
4
Verify 120VAC is present at the igniter leads during the ignition sequence
5
Check gas valve manifold pressure with a manometer (3.5 in WC natural gas, 10.0 in WC propane)
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Hot surface igniter
Gas valve
Burner assembly