T
7 blinks
Moderate
Trane · HVAC Systems (AC, Furnaces & Heat Pumps)
Gas Valve Circuit Fault
Quick Answer
Error code 7 blinks on your Trane HVAC Systems (AC, Furnaces & Heat Pumps) means: Gas Valve Circuit Fault. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Open or shorted gas valve coil winding
  2. Wiring fault between the control board and gas valve
  3. Control board gas valve relay failure
  4. Incorrect gas valve installed or incompatible
How to Fix It
1
Measure resistance across the gas valve coil terminals (typically 150-600 ohms)
2
Check wiring from the control board to the gas valve for continuity
3
Verify the gas valve part number is correct for the furnace model
4
Test for 24VAC at the gas valve terminals during a call for heat
5
Gas valve replacement involves gas line work and must be done by a licensed HVAC technician
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Gas valve
Valve wiring harness
Control board