e3
Moderate
Trane · HVAC Systems (AC, Furnaces & Heat Pumps)
Compressor Overcurrent Protection
Quick Answer
Error code E3 on your Trane HVAC Systems (AC, Furnaces & Heat Pumps) means: Compressor Overcurrent Protection. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Compressor drawing excessive amperage due to mechanical wear
  2. Low voltage supply to the outdoor unit
  3. Failed compressor start capacitor or contactor
  4. Compressor windings starting to short
  5. Locked rotor condition
How to Fix It
1
Measure compressor amperage with a clamp meter and compare to the rated load amps (RLA) on the nameplate
2
Check voltage at the outdoor unit disconnect (should be within 10% of rated voltage)
3
Test the compressor start capacitor and run capacitor with a multimeter
4
Test contactor coil and contact resistance
5
If compressor amperage significantly exceeds RLA, compressor replacement by a licensed HVAC technician is required
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Compressor start/run capacitor
Contactor
Hard start kit
Compressor (if failed)