Lennox · HVAC Systems (AC, Furnaces & Heat Pumps)
Flame Current Leaves Acceptable Range
Quick Answer
Error code 271 on your Lennox HVAC Systems (AC, Furnaces & Heat Pumps) means: Flame Current Leaves Acceptable Range. This is usually fixable — see the step-by-step guide below.
Likely Causes
  1. Flame sensor degrading and producing unstable readings
  2. Intermittent gas pressure causing flame instability
  3. Electrical interference on the flame sensor circuit
  4. Cracked flame sensor insulator
How to Fix It
1
Monitor flame current over several minutes to identify fluctuation patterns
2
Clean the flame sensor and check for stable readings above 1.5 microamps
3
Check gas pressure stability during operation with a manometer
4
Inspect the flame sensor insulator for hairline cracks
5
Replace the flame sensor if current readings are erratic after cleaning
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Flame sensor
Flame sensor gasket
Gas pressure regulator (if unstable)