Lennox · HVAC Systems (AC, Furnaces & Heat Pumps)
Indoor Coil Thermistor Fault
Quick Answer
Error code 290 on your Lennox HVAC Systems (AC, Furnaces & Heat Pumps) means: Indoor Coil Thermistor Fault. This is usually fixable — see the step-by-step guide below.
Affected Models
Likely Causes
  1. Disconnected or damaged indoor coil temperature sensor
  2. Thermistor reading out of range (open or shorted)
  3. Corroded sensor connector or wiring
  4. Sensor physically displaced from the coil
How to Fix It
1
Locate the indoor coil thermistor and check its connector for firm seating
2
Measure the thermistor resistance with a multimeter and compare to the resistance/temperature chart
3
Inspect the wiring from the sensor to the control board for breaks or damage
4
Verify the sensor is properly mounted to the evaporator coil surface
5
Replace the sensor if resistance is out of the expected range
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Indoor coil thermistor
Wire connectors
Sensor mounting clip