f3 e1
Moderate
Maytag · Dryers
Exhaust Thermistor Open or Short
Quick Answer
Error code F3 E1 on your Maytag Dryers means: Exhaust Thermistor Open or Short. This is usually fixable — see the step-by-step guide below.
Affected Models
Likely Causes
How to Fix It
1
Unplug the dryer and locate the exhaust thermistor on or near the blower housing assembly
2
Disconnect the thermistor wires and measure resistance with a multimeter; at room temperature expect approximately 10,000 ohms
3
Inspect the wiring from the thermistor to the control board for any breaks, pinching, or loose connectors
4
Clean lint buildup from around the thermistor and its mounting area
5
Replace the exhaust thermistor if the resistance reading is outside the expected range
Pro Tip
This fix requires some technical knowledge. If you're unsure about any step, consider contacting support or a qualified technician.
Parts You May Need
Exhaust thermistor (W10845463)
Wire connectors
Mounting clip
Related Error Codes