M
f3 e2
Easy Fix
Maytag · Dryers
Moisture Sensor Bar Malfunction
Quick Answer
Error code F3 E2 on your Maytag Dryers means: Moisture Sensor Bar Malfunction. This is usually fixable — see the step-by-step guide below.
Affected Models
Likely Causes
  1. Moisture sensor bars inside the drum are coated with fabric softener or dryer sheet residue
  2. Moisture sensor circuit on the control board has failed
  3. Broken or corroded wiring to the moisture sensor bars
  4. Physical damage to the sensor bars from zippers or buttons on clothing
How to Fix It
1
Locate the two metal moisture sensor bars on the front interior bulkhead inside the drum
2
Clean both sensor bars with rubbing alcohol and a soft cloth to remove all residue buildup
3
Inspect the wiring from the sensor bars through the front bulkhead to the control board for continuity
4
Run a test cycle with damp towels to verify the sensor bars detect moisture correctly
5
Replace the moisture sensor bar assembly if cleaning does not resolve the problem
Pro Tip
This is a common issue that most users can resolve without specialized tools. Try the first step before moving on to more complex solutions.
Parts You May Need
Moisture sensor bar assembly (W10833859)
Rubbing alcohol for cleaning